<?xml version="1.0" encoding="utf-8"?>
<Spec id="72" path="\c\4\c48941d7c7d121afa728349cda2b432e.pdf"><Text id="14024" page="2">Boiler Feedwater Pump Buyer Specified Item Description Units Imp Rev. 0 Seller&apos;s Offer Comments 1.02.13 Maximum Surface Design Temperature (for insulation/lagging design) °F 140 140 Pump Performance 1.03 1.03.01 See Comments Case #3 Seller to Identify Curve Defining Case Performance Guarantee Case 1.03.02 Guaranteed TDH at guaranteed capacity (HP discharge) ft 7878 Per Performance Case Summary 3421 1.03.03 Guaranteed capacity at guaranteed TDH (HP discharge) gpm Per Performance Case Summary 1.03.04 Brake horsepower at guaranteed TDH and capacity bhp By Seller 8395 pump shaft power + Voith losses as per KSB data sheet (tolerances + safety margin not added) 1.03.05 Guaranteed TDH at guaranteed capacity (IP discharge) ft 2453.7 Per Performance Case Summary 1.03.06 Guaranteed capacity at guaranteed TDH (IP discharge) 665 gpm Per Performance Case Summary 1.03.07 Auxiliary Power Guarantee Case - Fired Guarantee Case #2 kW By Seller 1.03.08 6490 Power at motor terminals Expected worst case aux power: 15kW Guaranteed auxiliary power consumption at motor terminals (inclusive of all test tolerances) This shall include all operating pumps, standby pumps, and auxiliaries. Auxiliary Power Guarantee Case - Unfired Guarantee 1.03.09 Case #6 kW By Seller 1.03.10 3800 Power at motor terminals Expected worst case aux power: 15kW Guaranteed auxiliary power consumption at motor terminals (inclusive of all test tolerances) This shall include all operating pumps, standby pumps, and auxiliaries. Pump capacity at run-out By Seller HP flow, case #8 1.03.11 3910 gpm TDH at pump run-out capacity ft By Seller 1.03.12 7234.3 1.03.13 NPSHR at pump run-out capacity ft By Seller 35.8 NPSH3%, case #8 1.03.14 NPSHR at design capacity By Seller ft 30.8 NPSH3%, case #3 By Seller 1.03.15 Minimum Continuous Stable Flow (MCSF) required 1250/1050 continuous / pump protection gpm HP TDH at MCSF By Seller information only 1.03.16 ft 9245 / 9270 1.03.17 IP TDH at MCSF ft By Seller 3248 maximum value, Tapping closed (= shut-off head) Pump efficiency By Seller 83.7 1.03.18 % Case#3, hot according to HI 1.03.19 Motor efficiency efficiency Per Section E1 96.90% @ 100%, minus IEC tolerance tolerance % 1.03.20 Overall pump and motor efficiency (At Curve Defining Point) % By Seller 88.6% Case #3 (Pump design), info only 1.03.21 Per Section E1 Required motor nameplate rating hp 10000 1.03.22 Maximum brake power required at run-out bhp Per Section E1 9018 pump shaft power + Voith losses as per KSB data sheet, case #8 (tolerances + safety margin not added) 1.03.23 By Seller not required Warm-up flow (if required) gpm</Text></Spec>